Key Benefits:
Highly Realistic Ventilation Training at an Affordable Cost
Use your own real equipment including bag-valve mask, non-invasive ventilation (CPAP/BiPAP), and ICU ventilators
Comprehensive Patient Assessment
Learners assess dynamic chest movement, x-rays, CT scans, sounds, and a true-to-life Patient Monitor
Ideal for Team Training
Patient can be transported from one location to another due to tetherless capability
Objective Feedback for Learners
Debrief environment with objective simulation data, and real-time feedback for BVM ventilation and CPR
User-Friendly Software
Intuitive patient control and scenario building.
Hassle-Free Setup
Quick and easy installation.
Patient Ventilator Interactions
This video series showcases Aurora, the Respiratory Training Simulator, with an unparalleled ability to simulate authentic patient–ventilator interactions. Each video was created using the Aurora, the Respiratory Training Simulator, connected to a real mechanical ventilator, highlighting specific respiratory challenges that clinicians encounter every day. These realistic interactions can serve as powerful stand-alone teaching tools or be integrated into more complex clinical scenarios—bringing hands-on ventilation training to life like never before.
Click here to watch the ventilator interactions.
![]()

IngMar Medical’s new Internal Simulated Lung (ISL) is based on the world-renowned ASL 5000® Breathing Simulator technology. This technology elevates medical training, offering a tetherless, internal system for creating realistic ventilator interactions. Compatible with nearly any mode of ventilation, it accurately simulates respiratory mechanics, maintains therapeutic PEEP levels, and breathes spontaneously while being ventilated, preparing healthcare professionals for a wide range of ventilation scenarios.
Aurora, the Respiratory Training Simulator, is designed for training healthcare professionals in the nuances of bag-valve-mask (BVM) ventilation. Users are able to practice and perfect their BVM techniques under various clinical scenarios while being provided with real-time feedback (e.g. volume, pressure, rate) on the breaths they deliver. With its advanced sensor technology and feedback mechanisms, the Aurora system accurately replicates the challenges faced during real-life respiratory emergencies.


Aurora, the Respiratory Training Simulator, enables healthcare practitioners to gain hands-on experience with non-invasive ventilation strategies, including management of a variety of respiratory disease states on CPAP and BiPAP. Aurora ensures that medical professionals build the competence and confidence to utilize non-invasive ventilation techniques effectively and safely in clinical settings.
By offering a highly realistic, hands-on experience with ventilator settings, alarms, and patient responses, Aurora, the Respiratory Training Simulator, is an essential tool in bridging the gap between theoretical knowledge and practical application in Critical Care or ICU environments. Ventilation equipment responds appropriately to a wide range of patient conditions and disease states, including Asthma, COPD, ARDS, and emphysema. You can also simulate patients who are breathing spontaneously while being ventilated, from weak effort to patients who are ready for extubation.

Support and Services
Our team of skilled professionals is dedicated to providing you with exceptional support, offering a range of services that cover everything from technical and clinical support to maintenance, repairs, and upgrades.
RespiSim® Learning Management System
IngMar Medical’s new Internal Simulated Lung (ISL) is based on the world-renowned ASL 5000® Breathing Simulator technology.
True-to-life Patient Monitor provides a variety of assessment information including ECG monitoring, end tidal CO2, blood pressure, oxygen saturation, x-rays and CT scans.
Take your bag-valve mask training to the next level. Learners feel the difference between changes in respiratory disease states while squeezing the bag. Use real-time tidal volume, pressure, rate, and minute ventilation data to assess your learners’ competency.
Improve the effectiveness of CPR training by offering immediate feedback on depth and rate of chest compressions.
Practice medication administration through IV and IO access.
Gain hands-on experience with non-invasive ventilation strategies, including management of CPAP and BiPAP.
Effectively train a wide range of ventilation topics including air trapping, weaning, lung protective ventilation, finding optimal PEEP, patient-ventilator synchrony, assisted vs. controlled breaths, and many more
- Resistance – 8 to 150 cmH20/L/sÂ
- Compliance – 3 to 150 mL/cmH20Â
- Breath rate – passive to 100 bpmÂ
- Patient effort (muscle pressure) – 0 to 50 cmH20Â
- Neural inspiratory time – 0.1 to 3.6 secondsÂ
- Tidal volume – Maximum 900 mLÂ
- Holds PEEP > 20 cmH20Â
- Simulate tracheal as well as left and right bronchial resistanceÂ
- Simulate independent inspiratory and expiratory resistanceÂ
- Simulate independent left and right lung complianceÂ
- Control patient’s work of breathing with variable patient effortÂ
- Spontaneous breathing recognized by a real mechanical ventilatorÂ
- Tetherless capability (run without wall power for at least 2 hours)
- Connect software wirelessly
- Pre-built lung models and scenarios provided by IngMar MedicalÂ
- Save custom lung models and scenariosÂ
- Simulate a cough breath during simulation with one clickÂ
- Randomize all lung parameters within a set boundaryÂ
- Trend each lung parameter individuallyÂ
- Vary lung parameters during scenario with immediate impact on ventilator waveformsÂ
- Change ventilation modes (e.g. volume to pressure control) seamlessly on the same patient without adjusting patient settings or interrupting the simulationÂ
- Adult and pediatric patients (12 year old and above)Â
- Anatomically realistic chest movementÂ
- Unilateral and bilateral chest movementÂ
- Anatomically correct airway allows for realistic oral and nasal intubation using OPA, NPA, iGel, LMA, LT, and ETTÂ
- Vascular access (IV/IO)Â
- Head tilt and chin liftÂ
- CPR with real-time feedbackÂ
- Bag-valve mask training with real-time feedbackÂ
- Gastric insufflationÂ
- Esophageal intubation
- Realistic, durable skinÂ
- True-to-life Patient Monitor provides learner with assessments during simulation
- Library of EKG and CO2 waveformsÂ
- 12 lead ECG displayÂ
- Heart, lung, and bowel sound auscultationÂ
- Interacts realistically with all modes of ventilation including Pressure/Volume Control, and spontaneous modes such as Pressure Support, ASV, and PAVÂ
- Interacts realistically with Bag-valve Mask (BVM) and Non-invasive Ventilation (NIV)Â
- Simulate any type of patient-ventilator dysynchrony scenario (inspiratory, expiratory, trigger, and cycle)Â
- Simulate spontaneous breathing trial or patient weaning scenariosÂ
The features of Aurora’s internal simulated lung (ISL) allows it to be utilized with any ventilator in the market.
Yes, not only can the simulator “trigger” the ventilator, but it can mimic apneic to fully breathing patients. Patients can have a range of spontaneous tidal volumes that interact realistically with a ventilator just as a human would. The user can simulate a patient who is breathing with support from the ventilator in spontaneous modes of ventilation, or trigger a ventilator driven breath in controlled modes of ventilation.
Conventional modes of ventilation can be utilized realistically with the simulator. This includes both invasive modes such as SIMV and full control modes and non-invasive modes like CPAP and BIPAP. Jet and High-frequency ventilation are not recommended.
Routine maintenance is not necessary for Aurora or its internal lung technology. Please monitor systems for leaks, and if leaks are detected, we recommend sending the system back in for replacement of seals/lubrication. However, this is not required maintenance if it does not interfere with simulator use on the ventilator.
The standard warranty covers repairs due to manufacturer’s defects or workmanship. It does not cover damages resulting from improper use, negligence, disassembly, unauthorized service, and unauthorized modification. Computer or monitors are excluded from the warranty. Manikin skin and anatomical shell is covered under a 2-year standard manufacturer’s warranty. All pneumatics and electrical components are covered separately. Extended warranty options do exist.
Each Aurora simulator will come with an Aurora manikin, a windows-based computer to run RespiSim® Software, a tablet to run the Patient Monitor application, and all additional components needed to run Aurora such as the power charger.
Included with the purchase of Aurora, the Respiratory Training Simulator, will be a subscription to RespiSim® LMS, which will allow for self-learning on the hardware and software for Aurora. Additional training options can be purchased separately, such as clinical consultation. Contact ingmar.support@3bscientific.com to discuss these options.
The use of 100% oxygen is not recommended for use with Aurora. We suggest the use of compressed air while ventilating Aurora.
The simulator can either connect via the internal network within Aurora wirelessly to the PC running the software, or via Ethernet connected from Aurora to the PC running the software. If hardwiring is required, Aurora must also be hardwired to the monitor running the Patient Monitor application.
Yes! The chest movement is dynamic featuring both bilateral and unilateral chest rise that is in sync with the patient and any form of ventilation being delivered. Depth and rate are also variable based on the patient’s breaths.
The simulator does not exhale real CO2, however we have simulated CO2 waveforms and values that can be set by the user within the RespiSim® software. This will provide realistic patient assessment without the maintenance of real CO2.
Want to learn more?
Submit this form, and a Product Specialist will contact you with more information.
